La-crosse-technology Radio Controlled Projection Alarm WT-5110 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hodiny La-crosse-technology Radio Controlled Projection Alarm WT-5110. La Crosse Technology Radio Controlled Projection Alarm WT-5110 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 40
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
WT-5110
433 MHz
Radio Controlled Projection Alarm
Instruction Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 39 40

Shrnutí obsahu

Strany 1 - Instruction Manual

WT-5110 433 MHz Radio Controlled Projection Alarm Instruction Manual

Strany 2

10 H. CHANGING DISPLAY MODE (INDOOR TEMPERATURE/HUMIDITY OR ALARM TIME) There are two possible display modes in the indoor temperature/humidity se

Strany 3

11SPECIFICATIONS FOR WT-5110 Temperature: Measuring range: 14°F to 99°F with 0.2°F resolution Checking intervals: Every 10 seconds Humidity Measuri

Strany 4

12WARRANTY INFORMATION La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and

Strany 5

13For warranty work, technical support, or information contact: La Crosse Technology, Ltd 2809 Losey Blvd. S. La Crosse, WI 54601 Phone: 608.782.16

Strany 6

1WS-9117U Wireless 433 MHz Temperature Station Instruction Manual

Strany 7

2TABLE OF CONTENTS Topic Page Inventory of Contents 3 Quick Setup 4-8 Detailed Setup Guide Battery Installation 9-11 Setting the Time 11-12 Sel

Strany 8

3INVENTORY OF CONTENTS 1. The indoor temperature station (Figure 1) 2. The remote temperature sensor (TX6U) and mounting bracket. (Figure 2) 3. 3

Strany 9

4QUICK SETUP Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries. 1. Have the indoor temperature station and remote tempera

Strany 10

5In this time the indoor temperature station and remote temperature sensor will start to talk to each other and the display will show both the indoor

Strany 11

6of resistance. Your distance plus resistance should not exceed 80 ft. in a straight line. NOTE: Fog and mist will not harm your remote temperature

Strany 12 - WARRANTY INFORMATION

2TABLE OF CONTENTS Topic Page Inventory of Contents/ Additional Equipment 3 About WWVB 3 Quick Set-Up Guide 4 Detailed Set-Up Guide Bat

Strany 13

7b. When you have your choice shown on the display press and release the “SET/CH” button once. 2. Degree Fahrenheit will now show. a. To change b

Strany 14

8the word TIME when in the PM hours. During the AM hours this area will be blank. b. When the correct hour is shown, press and release the “SET/CH”

Strany 15 - TABLE OF CONTENTS

9 DETAILED SETUP GUIDE I. BATTERY INSTALLATION A. REMOTE TEMPERATURE SENSOR 1. Remove the mounting bracket. 2. Remove battery cover 3. Observing

Strany 16

10B. INDOOR TEMPERATURE STATION Note: After the batteries are installed, DO NOT press any buttons. This may interfere with the signals, causing tem

Strany 17 - QUICK SETUP

115. The indoor temperature station should now show: “-:- -” in the TIME LCD, and temperatures in the INDOOR and OUTDOOR LCD’s. II. TIME A. SETT

Strany 18

125. Press and release the “SET/CH” button to move to the minute setting 6. Press and release the “MIN/MAX” button to set the minutes. 7. Press and r

Strany 19

133. Press and release the “MIN/MAX” button to shift between °F and °C. 4. Press and release the “SET/CH” button twice to activate settings. IV. FEA

Strany 20

14seconds. C. ADDING ADDITIONAL REMOTE TEMPERATURE SENSORS (OPTIONAL) 1. The WS-9117U is able to receive signals from 3 different remote temperature

Strany 21

15remote temperature sensor units, and in numeric sequence. Second, install batteries into the indoor temperature station. Transmission problems wi

Strany 22

16D. VIEWING AND OPERATING WITH MULTIPLE REMOTE TEMPERATURE SENSOR UNITS 1. To view the temperature of a different remote temperature sensor unit, pr

Strany 23

3INVENTORY OF CONTENTS 1) WT-5110 Alarm Clock 2) AC adapter/transformer 3) Instruction manual and warranty card. ADDITIONAL EQUIPMENT (not include

Strany 24

17V. MOUNTING Note: To achieve a true temperature reading, avoid mounting in direct sunlight. We recommend that you mount the remote temperature sen

Strany 25

18that is required is to place the indoor temperature station in an appropriate location. 2. To wall mount, remove the table stand. To do this, pull

Strany 26

19TROUBLESHOOTING NOTE: For problems not solved, please contact La Crosse Technology via e-mail or phone, or visit our website, www.lacrossetechnolo

Strany 27

20Problem: Temperatures do not match if units are placed next to each other. Solution: Each temperature sensor is manufactured to be accurate to with

Strany 28

21 MAINTENANCE AND CARE INSTRUCTIONS • Extreme temperatures, vibration, and shock should be avoided to prevent damage to the units. • Clean displa

Strany 29

22SPECIFICATIONS Transmitting Frequency 433MHz Measuring Temperatures Indoor Temperature Station: Indoor 32°F to 140°F with 0.2°F resolution. (0°C

Strany 30

23Temperature Station Dimensions: (H x W x D) Indoor Temperature Station 5 x 2.25 x 1 in (excluding table stand) (125 x 58 x 23 mm) Remote Temper

Strany 31

24purchase to La Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized service center. La Crosse Technology, Ltd will repair or replace t

Strany 32

25be presented to the carrier); (3) damage to, or deterioration of, any accessory or decorative surface; (4) damage resulting from failure to follow

Strany 33

26consequential or incidental damages therefore the above exclusion of limitation may not apply to you. For warranty work, technical support, or inf

Strany 34

4QUICK SET-UP GUIDE Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries. 1. We recommend beginning the set-up procedure at

Strany 35

27 Freq. 433.92 MHz La Crosse Technology Made in China WS-9117U FCC ID: OMO-01RX (Receiver), OMO-01TX (sensor) THIS DEVICE COMPLIES WITH PART 15 OF

Strany 36 - (128 x 40 x 23 mm)

5DETAILED SET-UP GUIDE I. BATTERY INSTALLATION A. PROJECTION ALARM 1. Remove the battery cover. 2. Observe the correct polarity, and install 2

Strany 37

6II. PROGRAM MODE To enter the Program Mode hold down the “MODE/MIN” button for 3 seconds, until the time flashes in the top of the display. The Pr

Strany 38

74. Press and release the “MODE/MIN” button to select the appropriate time zone. There are 24 time zones to choose from (based relative to the int

Strany 39 - FCC DISCLAIMER

8III. FEATURES & OPERATIONS A. FEATURES 1. Radio-controlled time 2. Projection of time 3. LED backlight 4. Display of indoor temperature/hum

Strany 40

9D. LED BACKLIGHT 1. The projection alarm has an LED backlight designed for night-viewing. This will light up for 4 seconds whenever the snooze bu

Komentáře k této Příručce

Žádné komentáře